SUMMARY
This issue was introduced in version 5.4.2402.1403 released on February 14, 2024, resolved in version 5.6.2409.701 released on September 9, 2024, then reintroduced in version 5.7.2410.1403 released on October 15, 2024.
AFFECTED VERSIONS
Product Name | Version | Release Date | History |
---|---|---|---|
Recast Right Click Tools Console Extension | 5.7.2411.1105 | November 13, 2024 | 273 days open |
Recast Right Click Tools Console Extension | 5.7.2410.1403 | October 15, 2024 | 244 days open (Reintroduced) |
Recast Right Click Tools Console Extension | 5.6.2409.701 | September 9, 2024 | 208 days open (Resolved) |
Recast Right Click Tools Console Extension | 5.6.2407.1103 | July 11, 2024 | 148 days open |
Recast Right Click Tools Console Extension | 5.5.2406.1703 | June 20, 2024 | 127 days open |
Recast Right Click Tools Console Extension | 5.5.2405.1503 | May 15, 2024 | 91 days open |
Recast Right Click Tools Console Extension | 5.5.2404.1007 | April 10, 2024 | 56 days open |
Recast Right Click Tools Console Extension | 5.4.2403.901 | March 13, 2024 | 28 days open |
Recast Right Click Tools Console Extension | 5.4.2402.1403 | February 14, 2024 | 0 day (Instantiated) |
BUG DEFINITION
When the Check for Bugfix Updates checkbox option is checked, and the update check is preformed (occurs once a day), the consumer receives a prompt stating A new Recast Software release is available!
UNEXPECTED USER EXPERIENCE
The prompt is a link for the currently installed version.
EXPECTED USER EXPERIENCE
If the version check is working correctly:
The prompt is a link for the bugfix update version.
Otherwise:
No prompt.